This instrument was designed by technical department of Huazheng Electric Manufacturing (Baoding) Co., Ltd.. Its performance is mainly reflected in:
u Breakthrough in self-test the boot a long time to wait, start immediately into the test.
u Breakthrough relay self-test mode, using advanced processing algorithms and digital integration technology, a fully intelligent.
u Break the old product to heavy issues, more in line with characteristics of handheld devices.
u New design, panel operation with 6 buttons, better performance.
u An increase of sound and light alarm, "beep—beep--beep --" alarm sound.
u Increase the interference signal recognition indicator.
u Improved anti-jamming capability and test stability.
u Stored data: 99 Units.
u Wider range: 0.01Ω-1200Ω
u Lower power consumption: Maximum operating current not exceeding 50mA.
HZRC series of Pincers Earth Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment.
HZRC series of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use.
HZRC series of Pincers Earth Tester can measure out the faults beyond the reach of the traditional methods, and can be applied in the occasions not in the range of the traditional methods.
HZRC series of Pincers Earth Tester can measure the integrated value of the grounding body resistance and the grounding lead resistance.
HZRC series of Pincers Earth Tester is equipped with a long jaw, as indicated in the figure below. A long jaw is particularly suitable for the occasion of grounding with the flat steel.
In addition,
C+ Pincers Earth Tester is also able to measure the leakage current and the neutral current in the grounding system
1.Model of Series
Model |
Jaw Size (mm) |
Range of Resistance (Ω) |
Range of Current (A) |
Storage Function |
Alarm Function |
HZRC2000+ |
65×32 |
0.01--1200 |
-- |
99 Units |
√ |
HZRC2000A+ |
65×32 |
0.01--200 |
-- |
99 Units |
√ |
HZRC2000C+ |
65×32 |
0.01--1200 |
0.0--20.0 |
99 Units |
√ |
HZRC2100+ |
φ32 |
0.01--1200 |
-- |
99 Units |
√ |
HZRC2100A+ |
φ32 |
0.01--200 |
-- |
99 Units |
√ |
HZRC2100C+ |
φ32 |
0.01--1200 |
0.0--20.0 |
99 Units |
√ |
Note: “√” means available.
2. Ranges and Accuracy of Measurement
Mode |
Range |
Resolution |
Accuracy |
Resistance |
0.010Ω-0.099Ω |
0.001Ω |
±(1%+0.01Ω) |
0.10Ω-0.99Ω |
0.01Ω |
±(1%+0.01Ω) |
|
1.0Ω-49.9Ω |
0.1Ω |
±(1%+0.1Ω) |
|
50.0Ω-99.5Ω |
0.5Ω |
±(1.5%+0.5Ω) |
|
100Ω-199Ω |
1Ω |
±(2%+1Ω) |
|
200Ω-395Ω |
5Ω |
±(5%+5Ω) |
|
400-590Ω |
10Ω |
±(10%+10Ω) |
|
600Ω-880Ω |
20Ω |
±(20%+20Ω) |
|
900Ω-1200Ω |
30Ω |
±(25%+30Ω) |
|
*Current (True-RMS) |
0.00mA -9.00mA |
0.05mA |
±(2.5%+2mA) |
10.0mA -99.0mA |
0.1mA |
±(2.5%+10mA) |
|
100mA -300mA |
1mA |
±(2.5%+20mA) |
|
0.30A-2.99A |
0.01A |
±(2.5%+0.1A) |
|
3.0A-9.9A |
0.1A |
±(2.5%+0.5A) |
|
10.0A-20.0A |
0.1 A |
±(2.5%+1 A) |
Resistance Measurement Frequency: >1KHz
Measured Current Frequency: 50Hz/60Hz
Setting Range of Resistance Alarm Critical Value: 1Ω-199Ω
*Setting Range of Current Alarm Critical Value:1mA -499mA
3. Specifications
Instrument safety: IEC/EN61010-1, IEC/EN6010-2-032
Insulation: double insulation
Pollution degree: class II
Overvoltage category: CAT III 150V to ground, Max 20A
Degrees of protection:
-IP30, Group III equipment as per EN 60529 Ed 92
-IK04, as per EN 50102 Ed 95
Dimensions(L×W×H):
-Long elliptic jaw: 285mm×90mm×66mm; (11×4×3 inches)
-Round jaw: 260mm×90mm×66mm;(10×4×3 inches)
Span of Jaw: Long elliptic jaw 35mm; round jaw 32mm
Weight (including batteries): Long elliptic jaw-1160g, Round jaw-1120g
Battery type: 4 ×1.5V alkaline LR6 AA battery
Low battery indication: is displayed
Internal consumption: <50mA
Auto Power off: after 5 minutes of idleness
Display: 4 LCD, sign, decimal point and backlight
Memory size: 99 Units of Reading
Environment (Temperature & Relative Humidity):
-Working: -10°C~55°C, 10%RH-90%RH
-Storage: -20°C ~60°C, below 70%RH
Range shift: Full range automatic shifting
External magnetic field: <40A/m
External electric field: <1V/m
Data upload interface: RS232 (Optional)