I. Feature
High-voltage insulation resistance tester, with 7 range: 500V, 1000V, 2500V, 5000V, 10000V, 15000V, ,20000V test up to 40TΩ,there is also a manual boost function.
● design in strict accordance with safety standards
● insulation resistance range: 40TΩ@20kV
● the short-circuit current can be adjusted up to 5mA.
● automatically display the test values of polarization index (PI), absorption ratio (DAR), leakage current and capacitance, dielectric discharge test (DD) and step voltage test (SV).
● excellent anti-interference performance. When the interference current reaches 2mA, the instrument still ensures the test accuracy.
● AC and DC voltage test function of the tested line to automatically identify AC or DC.
● two power supply modes: Powered by lithium battery, the endurance time can reach 6 hours.
At the same time, it can be charged in use. In case of power failure, it can automatically convert from AC power supply to battery power supply.
● the operation is simple , and the insulation resistance analog column can be displayed.
● digital filtering function. When the displayed value deviates due to external influence, the filtering function is used to reduce the influence.
● perfect protection function and prompt function for fuse burnout.
● data saving function and data export.
II. Specification Parameter
● Safety specifications
IEC 61010-1 cat.iv 600V pollution degree 2
IEC 61326 EMC specification: electrical equipment for testing, control and inspection
IEC60529 IP64 (closed state of outer box)
● AC power supply: 120V ± 10%, 50 / 60 Hz, 20 VA
● battery power supply: 16.8v lithium ion battery
● battery life: 5000V@100M , about 6 hours
● dimensions (L x W x H): 32cm x 27cm x 16cm
● weight: 3.8kg
● output voltage accuracy: 100% to 110% of nominal value
● output voltage monitoring accuracy: ± 5% ± 10V
● voltage measurement range: AC: 30-600v (50Hz / 60Hz), DC: 30-600v
● voltage measurement accuracy: ± 2% ± 3dgt
● current test range: 10mA
● current measurement accuracy: 5% + 0.2nA
● short circuit current: 2 to 5mA, adjustable output
● capacitance test range: 25uf
● capacitance test accuracy: ± 10% ± 0.03uf
● protection: 2% error, shielding 500KΩ leakage resistance under 100MΩ load
● analog display range: 100kΩ to 10TΩ
● digital display range: 10kΩ to 40TΩ
● insulation alarm: 0.01MΩ to 9999.99MΩ
● insulation resistance test range and accuracy (temperature: 23 ± 5 º C, relative temperature: 45 – 75% RH)
range accuracy |
500V |
1000V |
2500V |
5000V |
10000V |
15000V |
20000V |
Not specified |
<100K |
<100K |
<100K |
<100K |
<100K |
<100K |
<100K |
±5%rdg |
100K-10G |
100K -20G |
100K -50G |
100K -100G |
100K-200G |
100K-300G |
100K-400G |
±20%rdg |
10G-100G |
20G-200G |
50G-500G |
100G-1T |
200G-2T |
300G-3T |
400G-4T |
Not specified |
>100G |
>200G |
>500G |
>1T |
>2T |
>3T |
>4T |
Other voltages |